| Brand Name: | Rexroth |
| Model Number: | HEDE 11 A1-1X/100/K41G24/2/V (R901141184) |
| MOQ: | 1 |
| Price: | $418 |
| Payment Terms: | T/T |
| Component series | 1X |
| Weight | m | kg | 0.09 |
| Installation position | any | ||
| Ambient temperature range | ϑ | °C | -20 … +80 |
| Storage temperature range | ϑ | °C | -40 … +100 |
| Pressure measuring ranges | pN | bar | 100 | 250 | 400 | 100 | 250 | 400 | 100 | 250 | 400 | |
| Switching point | Setting range | bar | 5 | 12.5 | 20 | 5 | 12.5 | 20 | 5 | 12.5 | 20 | |
| Reset range | bar | 3 | 7.5 | 12 | 3 | 7.5 | 12 | 3 | 7.5 | 12 | ||
| Hydraulic fluid temperature range | ϑ | °C | -25 … 80 | -25 … +80 | -25 … 80 | -25 … +80 | -25 … 80 | -25 … +80 | ||||
| Materials in contact with the medium | V4A (1.4404), FKM | |||||||||||
| Operating voltage | UB | 18 … 36 VDC | ||
| Current consumption | I | mA | < 25 | |
| Short-circuit protection | clocked | |||
| Overload resistance | yes | |||
| Reverse polarity protection | yes | |||
| Voltage drop | U | V | < 2 | |
| Switching frequency | f | Hz | 100 | |
| Accuracy class 1) | % | < 2.5 | ||
| Repetition accuracy 1) | < 0.5 % | |||
| Switching cycles, minimum | 50 million | |||
| Protection class according to DIN EN 60529 | IP67 | |||
| Isolation resistance | R | MΩ | > 100 (500 VDC) | |
| Electro-magnetic compatibility | EMC EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | ||
| EMC EN 61000-4-3 HF radiated | 10 V/m | |||
| EMC EN 61000-4-4 Burst | 2 kV | |||
| EMC EN 61000-4-6 HF line-bound | 10 V | |||
| UL approval | UL 508 | |||
| 1) | of the measurement range end value |
In order to satisfy the “limited voltage current” requirements according to UL, the device must be supplied from a galvanically separated source and a overcurrent protection has to be provided.
For applications outside these parameters, please consult us!
| Brand Name: | Rexroth |
| Model Number: | HEDE 11 A1-1X/100/K41G24/2/V (R901141184) |
| MOQ: | 1 |
| Price: | $418 |
| Payment Terms: | T/T |
| Component series | 1X |
| Weight | m | kg | 0.09 |
| Installation position | any | ||
| Ambient temperature range | ϑ | °C | -20 … +80 |
| Storage temperature range | ϑ | °C | -40 … +100 |
| Pressure measuring ranges | pN | bar | 100 | 250 | 400 | 100 | 250 | 400 | 100 | 250 | 400 | |
| Switching point | Setting range | bar | 5 | 12.5 | 20 | 5 | 12.5 | 20 | 5 | 12.5 | 20 | |
| Reset range | bar | 3 | 7.5 | 12 | 3 | 7.5 | 12 | 3 | 7.5 | 12 | ||
| Hydraulic fluid temperature range | ϑ | °C | -25 … 80 | -25 … +80 | -25 … 80 | -25 … +80 | -25 … 80 | -25 … +80 | ||||
| Materials in contact with the medium | V4A (1.4404), FKM | |||||||||||
| Operating voltage | UB | 18 … 36 VDC | ||
| Current consumption | I | mA | < 25 | |
| Short-circuit protection | clocked | |||
| Overload resistance | yes | |||
| Reverse polarity protection | yes | |||
| Voltage drop | U | V | < 2 | |
| Switching frequency | f | Hz | 100 | |
| Accuracy class 1) | % | < 2.5 | ||
| Repetition accuracy 1) | < 0.5 % | |||
| Switching cycles, minimum | 50 million | |||
| Protection class according to DIN EN 60529 | IP67 | |||
| Isolation resistance | R | MΩ | > 100 (500 VDC) | |
| Electro-magnetic compatibility | EMC EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | ||
| EMC EN 61000-4-3 HF radiated | 10 V/m | |||
| EMC EN 61000-4-4 Burst | 2 kV | |||
| EMC EN 61000-4-6 HF line-bound | 10 V | |||
| UL approval | UL 508 | |||
| 1) | of the measurement range end value |
In order to satisfy the “limited voltage current” requirements according to UL, the device must be supplied from a galvanically separated source and a overcurrent protection has to be provided.
For applications outside these parameters, please consult us!